Create standardized controls designs, sequences of operations, points lists, BOMs, and Division 25 specs for modular data center builds. Coordinate across MEP teams for repeatable, error-free deployment of 50GW+ infrastructure.
200k – 250k
Hybrid7+ YOEHardware Engineering
About the role
Role Scope
Create template controls designs for fully modular data center builds, enabling one validated design set to deploy across every site.
Write sequences of operations defining how mechanical and electrical systems run; hand them to the programming team as the source of truth for code.
Build standard points lists and bills of materials that lock in instrumentation, IO, and controls hardware for every modular build.
Own the Division 25 integrated automation specification end to end, keeping it current as equipment, vendors, and site designs change.
Coordinate controls design across mechanical, electrical, and commissioning teams to ensure alignment with equipment and required tests.
Requirements
Produced controls design packages, drawings, points lists, or specifications that contractors or programmers built from without follow-up questions.
Written sequences of operations for mechanical or electrical systems and seen them implemented in real controllers.
Authored or owned a Division 25 integrated automation specification (or equivalent controls spec) and kept it accurate across multiple projects.
Built standard points lists and BOMs, understanding how errors lead to change orders.
Design for repeatability: turn one-off engineering into reusable templates.
Identify coordination gaps between mechanical, electrical, and controls scopes before they reach the field.
Nice-to-Haves
Data center mechanical and electrical systems (chiller plants, CRAH/CRAC, fan wall units, switchgear).
Modular or productized build delivery.
BMS and SCADA platforms over BACnet and Modbus.
CSI MasterFormat and Division 25 spec writing.
Points list and IO schedule tooling.
Skills
Controls DesignSequences Of OperationsPoints ListsBills Of MaterialsDivision 25 SpecificationBacnetModbusBmsScadaCsi MasterformatIo Scheduling
Own geotechnical engineering for 50GW+ data center development: lead subsurface investigations, interpret data for foundation and ground improvement decisions, perform fatal-flaw site screening, and coordinate with structural/civil/environmental teams across multiple states.
200k – 250k
Hybrid7+ YOEHardware Engineering
Reliability Engineer, Data Center Design
FluidstackAustin, TX +3
Build and maintain reliability models for 50GW+ data center designs using RBDs, FTAs, and Monte Carlo simulations to quantify P99 availability across MEP systems. Own reliability studies at design gates, manage consultants, and translate findings into actionable recommendations for SLAs and capital allocation.
200k – 250k
Hybrid7+ YOEHardware Engineering
Fire Protection Engineer, Data Center Design
FluidstackAustin, TX +3
Own end-to-end fire protection design and strategy for 50GW+ AI data centers, from concept through commissioning. Design/supervise VESDA, fire alarm, sprinkler and clean agent systems; serve as primary AHJ/fire marshal liaison to keep permitting off critical path; ensure integration with electrical/mechanical systems. Requires PE or NICET certification plus hands-on mission-critical facility experience.
200k – 250k
Hybrid7+ YOEHardware Engineering
Electrical Engineer, Substation Design
FluidstackAustin, TX +3
Lead HV/MV substation design up to 345 kV for hyperscale data center campuses, owning full design packages, engineering studies, equipment specs, and utility interconnections. Requires 8+ years of substation design experience and a bachelor's in electrical engineering.