Skip to content
FluidstackFluidstackAustin, TX

Fire Protection Engineer, Data Center Design

Own end-to-end fire protection design and strategy for 50GW+ AI data centers, from concept through commissioning. Design/supervise VESDA, fire alarm, sprinkler and clean agent systems; serve as primary AHJ/fire marshal liaison to keep permitting off critical path; ensure integration with electrical/mechanical systems. Requires PE or NICET certification plus hands-on mission-critical facility experience.

200k – 250k
Hybrid7+ YOEHardware Engineering

About the role

Role Scope

Own the fire protection scope of design packages from concept through construction documents across the data center portfolio, designing and specifying VESDA and addressable fire alarm, pre-action sprinkler, wet pipe, and clean agent suppression systems.

Serve as primary point of contact with local fire marshals and AHJs on every site, running plan reviews and negotiating code-compliant equivalencies on non-standard designs so permitting stays off the critical path.

Develop campus-level fire suppression strategy, coordinating water supply, distribution, and system redundancy across multiple buildings and phases of a build-out.

Review and approve fire protection submittals and shop drawings from EPC and equipment vendors, and validate third-party consultant designs for code compliance and consistency with standards before they advance to construction.

Support commissioning of fire detection and suppression systems with the Commissioning Agent, resolving test failures before sign-off, and provide fire protection input on capacity additions, retrofits, and incident-driven remediation on live sites.

Requirements

  • Personally designed, specified, and stood up fire detection and suppression systems for mission-critical, industrial, or large commercial facilities.
  • PE license in Fire Protection Engineering, or NICET Level III/IV certification in Fire Alarm Systems and Water-Based Systems.
  • Negotiated code-compliant alternatives directly with fire marshals and AHJs on non-standard designs.
  • Thorough working knowledge of NFPA 75, 76, and 2001, and FM Global's data center loss prevention requirements.
  • Coordinate fire protection design with electrical, mechanical, and controls engineering.
  • Write clearly enough that a system narrative, hydraulic calculation, or piece of AHJ correspondence still reads as the source of truth for a site years after written.

Nice-to-Haves

  • FM-200 and Novec 1230 clean agent systems in data center environments.
  • Multiple state or municipal AHJ jurisdictions.
  • Hyperscale or colocation campus design.
  • NFPA committee or code development involvement.

Skills

Fire Protection EngineeringVesdaAddressable Fire AlarmPre-Action SprinklerWet Pipe SystemsClean Agent SuppressionNfpa 75Nfpa 76Nfpa 2001Fm GlobalPe LicenseNicet CertificationAhj NegotiationHydraulic Calculations
Fluidstack

Geotechnical Engineer, Data Center Design

FluidstackAustin, TX +3

Own geotechnical engineering for 50GW+ data center development: lead subsurface investigations, interpret data for foundation and ground improvement decisions, perform fatal-flaw site screening, and coordinate with structural/civil/environmental teams across multiple states.

200k – 250k
Hybrid7+ YOEHardware Engineering
Fluidstack

Reliability Engineer, Data Center Design

FluidstackAustin, TX +3

Build and maintain reliability models for 50GW+ data center designs using RBDs, FTAs, and Monte Carlo simulations to quantify P99 availability across MEP systems. Own reliability studies at design gates, manage consultants, and translate findings into actionable recommendations for SLAs and capital allocation.

200k – 250k
Hybrid7+ YOEHardware Engineering
Fluidstack

Controls Engineer, Design Development

FluidstackAustin, TX +3

Create standardized controls designs, sequences of operations, points lists, BOMs, and Division 25 specs for modular data center builds. Coordinate across MEP teams for repeatable, error-free deployment of 50GW+ infrastructure.

200k – 250k
Hybrid7+ YOEHardware Engineering
Fluidstack

Electrical Engineer, Substation Design

FluidstackAustin, TX +3

Lead HV/MV substation design up to 345 kV for hyperscale data center campuses, owning full design packages, engineering studies, equipment specs, and utility interconnections. Requires 8+ years of substation design experience and a bachelor's in electrical engineering.

200k – 250k
On-site8+ YOEHardware Engineering
Fluidstack

Electrical Engineer, Modular Design & Manufacturing

FluidstackAustin, TX +3

Senior Electrical Engineer designing modular, factory-built electrical infrastructure (e-houses, switchgear skids, prefabricated rooms) for gigawatt-scale data centers. Owns end-to-end design, standardization, vendor collaboration, and site integration.

200k – 250k
On-site7+ YOEHardware Engineering