Lead HV/MV substation design up to 345 kV for hyperscale data center campuses, owning full design packages, engineering studies, equipment specs, and utility interconnections. Requires 8+ years of substation design experience and a bachelor's in electrical engineering.
200k – 250k
On-site8+ YOEHardware Engineering
About the role
Responsibilities
Lead HV/MV substation design (up to 345 kV and above) and MV distribution interfaces for hyperscale campuses, from concept through IFC and energization.
Review and approve EPC- and consultant-produced deliverables: physical/structural layouts, electrical drawings, protection & control packages, and construction documents.
Perform and review engineering calculations and studies: load flow, short circuit, arc flash, grounding and bonding, lightning, insulation coordination, relay coordination, and cable ampacity.
Develop scopes of work, RFPs, and equipment specifications for long-lead equipment (transformers, switchgear, breakers); run technical bid evaluations and witness factory acceptance tests.
Provide technical input to utility interconnection processes and agreements (ESAs/CDAs), coordinating with ISOs/RTOs and utility engineering teams.
Support construction, commissioning, and phased energization planning, including resolution of field issues and RCAs.
Requirements
Bachelor's degree in Electrical Engineering.
8+ years of experience in HV/MV substation design (transmission and distribution voltages, up to 345 kV).
Demonstrated ownership of full substation design packages: one-lines/three-lines, physical layouts, grounding, raceway, and protection & control drawings.
Experience developing equipment specifications, running technical bid evaluations, and witnessing factory acceptance tests for major HV/MV equipment.
Nice-to-Haves
Professional Engineer (PE) license.
Owner-side experience at a hyperscale data center operator or large industrial developer.
Direct experience with utility interconnection processes and technical inputs to ESAs/CDAs in ERCOT, PJM, MISO, or CAISO.
Experience with both AIS and GIS substation architectures.
Track record of standards authorship: Basis of Design documents, standard drawing libraries, commissioning scripts, responsibility matrices.
Own geotechnical engineering for 50GW+ data center development: lead subsurface investigations, interpret data for foundation and ground improvement decisions, perform fatal-flaw site screening, and coordinate with structural/civil/environmental teams across multiple states.
200k – 250k
Hybrid7+ YOEHardware Engineering
Reliability Engineer, Data Center Design
FluidstackAustin, TX +3
Build and maintain reliability models for 50GW+ data center designs using RBDs, FTAs, and Monte Carlo simulations to quantify P99 availability across MEP systems. Own reliability studies at design gates, manage consultants, and translate findings into actionable recommendations for SLAs and capital allocation.
200k – 250k
Hybrid7+ YOEHardware Engineering
Fire Protection Engineer, Data Center Design
FluidstackAustin, TX +3
Own end-to-end fire protection design and strategy for 50GW+ AI data centers, from concept through commissioning. Design/supervise VESDA, fire alarm, sprinkler and clean agent systems; serve as primary AHJ/fire marshal liaison to keep permitting off critical path; ensure integration with electrical/mechanical systems. Requires PE or NICET certification plus hands-on mission-critical facility experience.
200k – 250k
Hybrid7+ YOEHardware Engineering
Controls Engineer, Design Development
FluidstackAustin, TX +3
Create standardized controls designs, sequences of operations, points lists, BOMs, and Division 25 specs for modular data center builds. Coordinate across MEP teams for repeatable, error-free deployment of 50GW+ infrastructure.